Displaying report 1-1 of 1.
Reports until 08:04, Thursday 02 May 2019
LHO General
corey.gray@LIGO.ORG - posted 08:04, Thursday 02 May 2019 - last comment - 09:50, Thursday 02 May 2019(48915)
OWL Operator Summary

TITLE: 05/02 Owl Shift: 07:00-15:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY:

130-sec-period ASC yaw oscillation continues.  Attaching ASC ndscope (template from "Locking" medm) which shows the oscillation seen on ASC PRC1 and noisiness seen on ASC DC1 & 2 (which don't quite line up with each other).  This has probably already been looked at, but just posting for kicks.

ALSx & y are no longer on DIAG_MAIN (see earlier alog).

Temperature issues observed at mid stations and EY (Bubba notified and commented on my entry).
LOG:

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 09:50, Thursday 02 May 2019 (48931)

Here's a few interesting things I found for the lock loss:

1st attachment - Doesn't show any signs of struggle really.

2nd attachment - Bit of a glitch right before the lock loss?

On the lock loss page there are a few signals that are looking suspect a few seconds before the lock loss (IMC WFS, LCS_REFL_A_LF, more), but nothing that I can make a inference about.

Images attached to this comment
Displaying report 1-1 of 1.