Reports until 11:01, Thursday 02 May 2019
H1 General
thomas.shaffer@LIGO.ORG - posted 11:01, Thursday 02 May 2019 - last comment - 15:20, Thursday 02 May 2019(48934)
Out of Observing for Cal Meas. 1800 UTC
Comments related to this report
thomas.shaffer@LIGO.ORG - 12:27, Thursday 02 May 2019 (48938)

Back to Observing 1925 UTC.

While we were out we tested turning on and off the SQZ noise eater. It clearly made the ~103Hz line come up and disappeared. So, we left it off and the associated SDF is attached.

Images attached to this comment
thomas.massinger@LIGO.ORG - 15:20, Thursday 02 May 2019 (48942)DetChar

TJ, Andy, Josh

For visualization purposes, we lined up the noise eater toggle with a spectrogram of the SQZ laser and h(t). The state switches line up perfectly and the wandering line in h(t) disappears when the noise eater is switched off.

See attached time series and spectrograms.

Images attached to this comment