Reports until 16:10, Thursday 02 May 2019
H1 DetChar (DetChar)
pep.covas@LIGO.ORG - posted 16:10, Thursday 02 May 2019 - last comment - 17:29, Thursday 02 May 2019(48947)
Lines at ~40.93 and ~46.09 coherent with SRCL and PRCL

After running another bruco analysis (https://ldas-jobs.ligo-wa.caltech.edu/~pep.covas/bruco/1240824092/) I found coherence around these two lines with several channels related to SRM and PRM.

I found these lines in the coil driver monitors of PRM and SRM, and also in some sensors like LSC-REFL_A_RF45_I_ERR_DQ and LSC-REFL_B_RF9_Q_ERR_DQ. I traced these signals back to the controls signals of the loop LSC-SRCL_OUT and LSC-PRCL_OUT, which also show increased coherence around these frequencies.

I checked more channels with DTT, and apparently these lines are there for LSC signals, but not ASC signals. Jeff has suggested that some notches around these frequencies could be applied to the LSC loops in order to suppress these lines.

Images attached to this report
Comments related to this report
pep.covas@LIGO.ORG - 17:29, Thursday 02 May 2019 (48951)

More coherent lines found:

17.8 Hz, see first image

27.71, second image

Images attached to this comment