possible correlation between h1edc DAQ-CRC errors and slow NFS access

On Tuesday 23rd April I turned on a ZFS scrub for the /opt/rtcds file system and we got a skew of h1edc CRC errors until I stopped the scrub.

To investigate this further, I wrote  a script which creates a 1GB file on both the /ligo and /opt/rtcds file systems from a workstation. This runs every 5 minutes and writes the disk-access speed into two EPICS records (units = MB/s).

At 04:49 PDT this morning we got 4 CRC errors, which in this case correlated to a slow down of /opt/rtcds access speed of 30%.

Attached plot shows past 48 hour trend of h1edc CRC (upper ndscope plot) and file access speed (lower strip-tool) which have been aligned on their x-axis. The strip tool shows /opt/rtcds access speeds (blue line) and /ligo (green line).

Note:

Both /ligo and /opt/rtcds slowed down this morning between 2am and 9am, with /opt/rtcds significantly slowing around 5am.

The previous CRC error of 3 counts from almost 48 hours ago is not related to disk slow down.

/opt/rtcds/ also slowed between 4am and 6am Thursday morning.

Jonathan checked that network statistics between the hours of 2am and 9am this morning,  nothing unusual was found (core switch showed a slight traffic increase between 2am and 4am).

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 13:01, Friday 03 May 2019 (48964)

Jonathan, Dave:

One way a NFS file system slow down could impact  h1edc is during its periodic calculation of the file-checksum for the file H1EDC.ini. To further test this, Jonathan made a RCG-branch3.5 change on the DTS to take  this checking out of x1edc (alog link below). This has been running for 90mins with no errors. Overnight last night x1edc raised 700+ CRC errors, so by Monday we should have a definitive result.

https://alog.ligo-la.caltech.edu/TST/index.php?callRep=12509

Displaying report 1-1 of 1.