patrick.thomas@LIGO.ORG - posted 22:30, Saturday 04 May 2019 (48985)
Observing
05:20:39 UTC

Accepted the attached SDF differences. The squeezer manager was giving 'TTFSS EOM noisy' notifications and was not proceeding past LOCK_TTFSS. Jenne had me turn on the squeezer noise eater. The SDF differences in the second screenshot are for that. The differences in the first screen shot are for the RF36 phasing. They will come back after running the script in Jenne's alog 48948 in a couple of hours.