May be interesting...

13:15UTC noticed H1IFO_RANGE.adl dipped into -1 Mpc and noticed momentary noise on DARM blrms shown below different from typical glitches.

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 10:59, Sunday 05 May 2019 (49005)DetChar

This started about 17:45UTC: Some Squeezer Noise Eater foolishness?

Images attached to this comment
andrew.lundgren@LIGO.ORG - 11:16, Sunday 05 May 2019 (49006)DetChar, ISC, OpsInfo, SQZ
Yes, this is the squeezer again. It can be diagnosed by a big comb appearing on most of the squeezer fast channels - I usually use H1:SQZ-LASER_IR_LF_OUT_DQ (first plot).

A simple way to diagnose this might be to put up a running trace of H1:SQZ-LASER_IR_LF_OUTPUT, which is a 16 Hz channel. It gets noticeably wider when the noise appears (second plot).
Images attached to this comment
edmond.merilh@LIGO.ORG - 11:23, Sunday 05 May 2019 (49007)

This all settled down ~ 18:05UTC

daniel.sigg@LIGO.ORG - 11:46, Sunday 05 May 2019 (49008)

Just turn the noise eater off: Squeezer Overview -> click on the laser.

edmond.merilh@LIGO.ORG - 13:38, Sunday 05 May 2019 (49010)

Will do, DS.