SUMMARY: Wish I could say I actively curred H1's issue tonight, but all I can say is my breakfast got us back to OBSERVING after ~4hrs of being DOWN.
Below is a summary of with highlights in bold.
The SRCL FF is fine the way it is with the many filters engaged. On Thursday (alog 48950) I had reverted to the setup where only FM3 was engaged, since it seemed a teensy bit better, which is why Corey saw this diff. But, I had only changed the filters by hand - I forgot to change the guardian code to reflect this revert, so the next time we acquired lock, guardian turned on all of the newer filters. This isn't a much worse feedforward than using only FM3, so it's fine that we ran this way during the weekend.
To find these filter banks, go to the LSC Overview screen, then on the left side, about 2/3 of the way down the screen there is a small button called IFO_FF, as well as a little matrix next to it. Those are the feedforward settings.
Since we are unlocked for the earthquake, I reloaded the ISC_LOCK guardian to use only the Feb28 FM3 for SRCLFF, and accepted this in both the safe and observe snap files, so hopefully no diffs will come up next time we try to go to observing.