Reports until 15:56, Tuesday 07 May 2019
H1 ISC
jenne.driggers@LIGO.ORG - posted 15:56, Tuesday 07 May 2019 - last comment - 11:26, Wednesday 08 May 2019(49077)
Rephased AS RF36 WFS a few minutes after getting to 35W

Keita made the point that we should phase AS36 where it needs to be for putting the BS signal all in one quadrant, and then use the MICH ASC offset if we need to adjust the BS pointing at 35W.  Keita, looking at the BS resonances while we're in lock, guesses that we're using a phase about 70 degrees away from what we should be.

When we had ~just gotten to 35W IFO lock I put in a BS pitch dither line at 8 Hz with 600 counts, and phased AS36 to minimize the peak in AS_A_RF36_I_PIT.  So far, the ASC seems okay, although we're only about an hour into the lock.  This doesn't put the SUM of Q to zero, which leaves us vulnerable to DC centering-like effects.

As Daniel has already noticed, to do this I have moved the AS_A_RF36 phase 34 degrees opposite of what I had been asking operators to do, which puts us 74 degrees different from what we had been using for the later parts of lock (after about 90 mins).  This is nearly exactly what Keita had guessed by roughly eyeballing some spectra.  The next question becomes: how was it working at all?? Have we basically not been controlling our BS motion for the last few days?  I'm hopeful, although haven't confirmed, that we'll be able to acquire lock with this phase and not have to change things part way through the lock, with the idea that we had been acquiring with a phase about 40 degrees wrong, but then moving it a further 30 degrees in the wrong direction made the gain in MICH ASC so low that we weren't controlling the BS, which is why we struggled to lock.

 

 

Comments related to this report
daniel.sigg@LIGO.ORG - 16:38, Tuesday 07 May 2019 (49087)

Another way to phase the RF36 is to put the entire sum signal into the in-phase. This way the quad-phase, which is used for MICH angular control, is insensitive to centering.

jenne.driggers@LIGO.ORG - 17:44, Tuesday 07 May 2019 (49088)

After the GRB stand down was over I did this; I moved the AS_A_RF36 phases by another -28 degrees to zero the Q SUM.  This made the yaw ASC oscillations significantly smaller, although I'm not sure that they're completely gone. 

This is now 60 degrees different from the 2W value that we'd been using, and 101 degrees different from the NomLowNoise value that we'd been using.  Gah, so confusing how the ASC was even working. 

If the IFO is fussy on relock, you can still run the 'revert' command from alog 48948:

z write H1:ASC-AS_A_RF36_SEG1_PHASE_R -175 H1:ASC-AS_A_RF36_SEG2_PHASE_R -190 H1:ASC-AS_A_RF36_SEG3_PHASE_R -170 H1:ASC-AS_A_RF36_SEG4_PHASE_R -175

But, I'm hopeful that we'll be able to relock with this new phasing.  We'll see....

jeffrey.bartlett@LIGO.ORG - 11:26, Wednesday 08 May 2019 (49116)
   The ASC Yaw signal is oscillating after the IFO has been up for the last few hours. Spoke with Jenne, and said to run the following command:

  z step H1:ASC-AS_A_RF36_SEG1_PHASE_R -1,28 H1:ASC-AS_A_RF36_SEG2_PHASE_R -1,28 H1:ASC-AS_A_RF36_SEG3_PHASE_R -1,28 H1:ASC-AS_A_RF36_SEG4_PHASE_R -1,28 -s 1