Displaying report 1-1 of 1.
Reports until 08:08, Monday 13 May 2019
H1 General
travis.sadecki@LIGO.ORG - posted 08:08, Monday 13 May 2019 - last comment - 12:18, Tuesday 14 May 2019(49203)
Ops Day Shift Transition

TITLE: 05/13 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 112Mpc
OUTGOING OPERATOR: Cheryl
CURRENT ENVIRONMENT:
    Wind: 4mph Gusts, 3mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.32 μm/s
QUICK SUMMARY:  Lock is 15+ hours old.  HWS code for ITMy, ETMx, and ETMy has stopped according to DIAG_MAIN.

Comments related to this report
georgia.mansell@LIGO.ORG - 11:27, Monday 13 May 2019 (49204)TCS

I have done the following:

  • ssh'd into the hws computers (h1hwsmsr, h1hwsmsr1, h1hwsex, h1hwsey),
  • opened tmux sessions (tmux attach)
  • found seg fault, screenshot in first attachment
  • I ran the thinning script (thin)
    • even after running the thinning script it seems like we're filling up these computers faster than we can keep up with (compare second attachment with the capacity after TJ deleted a bunch of stuff last wednesday).
  • and just restarted Hartmann code (python run_HWS.py -c {0/1} where IY EX and EY are 0, and IX is 1)

I'm not sure if this was the right thing to do; let's see if this keeps it alive during today's CO2 test.

Images attached to this comment
thomas.shaffer@LIGO.ORG - 12:18, Tuesday 14 May 2019 (49230)TCS

I ran the thinning scripts for all 4 camera directories. ITMY seemed to remove the most by far. We are now at 82% capacity on /data

I am in the process of making a script to automate the thinning and checking that the files were backed up, but until then we will need to keep an eye on this.

Displaying report 1-1 of 1.