Displaying report 1-1 of 1.
Reports until 10:14, Tuesday 14 May 2019
H1 PEM
jeffrey.bartlett@LIGO.ORG - posted 10:14, Tuesday 14 May 2019 (49226)
Monthly Dust Monitor Vacuum Pump Check (FAMIS #12987)
Hugh & Jeff B.,

   Checked the dust monitor vacuum pumps. Adjusted the vacuum pressure at End-Y; all others were within spec. All pump temperatures are within spec. 

   There is a bit of carbon build up on the exhaust muffler on the End-Y pump. Will continue to monitor this pump for a future rebuild. 

   Closing FAMIS #12987 