We haven't reset our initial alignment setpoints in a long time, and it likely needs redoing.
In prep for resetting the initial alignment setpoints, we need to have the IFO aligned and converged, but held at 2W. We also need the green shutters open and the green lasers locked on the TEM00 mode. With our current IR alignment and green QPD setpoints, the Xarm green doesn't want to lock on the 00 mode. Last lock I had opened the green shutters before the ADS loops came on for the arms, and the Xarm was locked on 00 for green, so I started running the green QPD setpoint script so that the green beam would follow along as the soft ADS loops converged. This seemed to be working, and the QPD offsets that had the Xarm green locked were:
ALS-X_QPD_A_PIT = -0.268
ALS-X_QPD_A_YAW = 0.708
ALS-X_QPD_B_PIT = 0.955 (this is extremely close to the edge, but it seemed okay hanging out here. The current value is 0.841)
ALS-X_QPD_B_YAW = -0.177
So, I think we should be able to slowly walk the offsets to this place during a future lock, or to use them for initial alignment if we also change the camera setpoint to be 251.2 for pitch, and leave yaw at the current value of 332.9 (the yaw CAM_ITM_YAW_ERR was basically zero, but the pitch was about 0.19). These setpoints wouldn't be our final answer for initial alignment setpoints, but would make it such that the Xgreen would lock on the 00 mode when the IFO is aligned with IR.
A somewhat confusing side note is that changing the QPD setpoints while in lock seems to have broken the lock twice when taking steps of size 0.1. Not totally sure why, but we're going to try this time to acquire without touching the offsets.
[Sheila, Jenne]
We have now reset the X and Y green initial alignment setpoints. Both arms' B pit offsets are extremely large - 0.96 - so we will need to pico these at some point, unless with the higher input power we decide that we need to move our spots (hopefully in a way that bring these closer to zero).
Attached is a screenshot of the QPD and ITM camera offsets after we reset them. We have now reverted this because we weren't able to make it through ANALOG CARM and DRMI on POP with the new alignment references.
We also found that the auto exposure was on for the ITMY green camera, it got turned on May 7th. This was causing glitches in the Y camera loop, we have turned it off.
We lost lock while powering up after this, so Niko ran an initial alignment.
Since we had so many locklosses this evening, we noticed a few more things that we could improve in the locking sequence.
We had a 0.5Hz pitch instability when reducing the RF45 modulation depth twice today, the second time I turned back on the 0.5 Hz notches in the pitch refl centering loops, which we had turned off last thursday (49160) (turning them off hadn't caused any problems until tonight).