Reports until 09:37, Wednesday 15 May 2019
H1 General
corey.gray@LIGO.ORG - posted 09:37, Wednesday 15 May 2019 (49262)
Initial Alignment & GWIstat Notes

1) Initial Alignment 

ALSy did not look normal.  Started out looking nice with unlocked flashing just under 1, but after going to the INITIAL_ALIGNMENT state, the video looked much less active and much less flashing (and obviously no locking).  Went to UNLOCKED and the flashes now looked much more noisy on ndscope.  

While in UNLOCKED, decided to still touch up alignment by adjusting the ETMy.  Managed to get flashes above 1.  Went to INITIAL ALIGNMENT state and Y-arm immediately locked up!  (This is different with Y-arm being very sensitive to alignment needed to lock.)  Moved on to rest of alignment after this.

No other issues with all other INITIAL ALIGNMENT steps.

2) GWIstat: "Calib issue"

When I brought this tool up, noticed this was showing a newish status:  "Calib issue".  Apologies if this is a known issue, this was just new to me.