Displaying report 1-1 of 1.
Reports until 00:20, Wednesday 22 May 2019
H1 General (PSL)
edmond.merilh@LIGO.ORG - posted 00:20, Wednesday 22 May 2019 (49395)
PSL Status Report - Weekly FAMIS# 11013

  Laser Status:
    Front End Power is 32.08W (should be around 30 W)
    70W Output Power is 69.49W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 7 days, 14 hr 19 minutes (should be days/weeks)
    Reflected power = 10.04Watts
    Transmitted power = 54.78Watts
    PowerSum = 64.81Watts.

    FSS:
    It has been locked for 0 days 7 hr and 5 min (should be days/weeks)
    TPD[V] = 2.543V (min 0.9V)

    ISS:
    The diffracted power is around 2.2%
    Last saturation event was 0 days 7 hours and 5 minutes ago (should be days/weeks)


    Possible Issues:

 