After the last lockloss a few things occurred:
- IM2 & 3 were adjusted to post-EQ values (Cheryl)
- Green Shutters were closed on both ISC tables at end stations (not sure if this was normal or not, but it stumped me until Georgia pointed it out). Then ran an alignment with new (restored) IM-values.
- For locking did have a few locklosses at LOCKING_ALS & this might be due to the FSS? Georgia said we might have to change the FSS COMM gain gain again if there are more problems at this state. At any rate, did make it through this and made it all the way to NLN. At OFFLOAD_DRMI_ASC, did hang out here for a while. Tweaked up POP18 via mainly SRM & this took POP18 to its preferred ~60counts. This also quieted down the POP18 & PR_GAIN signals.
SDF Diffs at NLN:
- PSL FSS common gain---> significant digit issue: ACCEPTED
- IM2 & IM3 pitch offsets: ACCEPTED
- TMSX pit & yaw offsets: ACCEPTED
Out of OBSERVING from 23:37 - 2:32utc.