Reports until 21:44, Monday 27 May 2019
H1 SQZ (SQZ)
georgia.mansell@LIGO.ORG - posted 21:44, Monday 27 May 2019 - last comment - 21:53, Monday 27 May 2019(49483)
Squeezer stuck at LOCK_CLF, fixed by init'ing the SQZ_MANAGER GRD

The squeezer got stuck trying to lock the CLF tonight. I thought this could be related to the low LO power at the CLF demoduator (see attached screenshot), but it looks like this level has been low for a while. Corey init'd the SQZ_MANAGER guardian and it locked the CLF just fine so we don't know what was actually causing the problem.

 

(We initially thought that since CLF_REFL_RF6_DEMOD was super low (-50) that we needed to align the ZM's but we were confusing the LO and CLF loops -- the RF6 was low because the beam diverter was closed and does not get opened until the next step in the locking sequence.)

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 21:53, Monday 27 May 2019 (49485)

Attached are the SQZ guardian nodes & logs we had when the SQZ was having its issues.

Images attached to this comment