Green arms now use WFS for both ETMs and TMS during main acquisition sequence

The Xarm green WFS were struggling a bit during re-acquisition this morning, so Sheila tried enabling the TMS WFS as well as the usual ETM WFS in the LOCKING_ARMS_GREEN state.  This worked well, and she has previously also had it work for the Yarm, and has made a guardian state to do this in the ALS_ARMs. 

I have now changed the ALS_ARM guardians to use the 2 WFS version (ETM and TMS) in the main path, and the ETM-only version is now on the side branch.  This also required a change in ISC_LOCK guardian to request the 2 WFS state. 