Reports until 19:29, Friday 31 May 2019
H1 CAL
aaron.viets@LIGO.ORG - posted 19:29, Friday 31 May 2019 (49587)
New GDS filters for LHO

[M. Wade, A. Viets]

I have produced new filters for the GDS calibration pipeline, nearly identical to those discussed in LHO aLOG 48546.  The only difference is that they do not contain an additional high-pass filter for the actuation path.  The reason for this is related to the first bug fix noted in gstlal-calibration-1.2.10.  These filters will be run on the testing DMT, where gstlal-calibration-1.2.10 has also been installed, to see that everything is working as expected before they are used in the production pipeline.

The filters are found in the calibration SVN, revision 7671, in this location: aligocalibration/trunk/Runs/O3/GDSFilters/H1GDS_1243387557.npz

Bode plots of the filters compared to the frequency domain model are attached.

Images attached to this report