Reports until 11:40, Wednesday 19 December 2012
H1 ISC
corey.gray@LIGO.ORG - posted 11:40, Wednesday 19 December 2012 - last comment - 15:59, Wednesday 19 December 2012(4968)
HAM1 WFS Sled Documentation Notes

This HAM1 WFS Sled was completed & bagged/stored back in Oct/Nov by Keita.  I opened it up to document a few items (optical component distance, photos, & parts used).  After noting everything I needed, the Sled was wrapped back up & stored in its plastic bin under the Optics Table in the Optics Lab.  It will stay here until installation.  Keita will submit an a document about this Sled to the DCC separately.

Optical Component Distances

For measurements below, the lenses are measured on the "backface" of their Lens Holder.  The Mirrors & Beam Splitters are measured on their glass "front faces".  All measurements in mm.

Photographs

An overall photo of this Sled layout is attached to this entry.  All photos of this Sled are located in ResourceSpace, here.

List Of Components Installed

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 15:59, Wednesday 19 December 2012 (4974)

DCC document is this: T1200555

According to me, L1 to L2 was measured 198.5mm, not 198mm.