Displaying report 1-1 of 1.
Reports until 17:07, Wednesday 19 December 2012
H1 SUS
mark.barton@LIGO.ORG - posted 17:07, Wednesday 19 December 2012 - last comment - 12:22, Thursday 20 December 2012(4977)
MC1 and MC3 TFs
Mark B.

Starting TFs on MC1 and MC3 at 17:05.
Comments related to this report
mark.barton@LIGO.ORG - 07:54, Thursday 20 December 2012 (4980)
Mark B.

Checked at 06:35. MC1 was done:

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC1/SAGM1/Data/2012-12-19-1040023911_H1SUSMC1_M1_0p01to50Hz_tf.mat

L and T plots are pristine but V, R, P, and Y have major dropouts in centre section, so can't for sure say healthy. Will redo everything with DTT.

MC3 was still running, reporting 167 minutes to go, i.e., about 09:00 am finish. Will probably let run while working on MC1 and then decide whether to redo with DTT.
mark.barton@LIGO.ORG - 12:22, Thursday 20 December 2012 (4983)
Mark B.

MC3 data also had dropouts: 

/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC3/SAGM1/Data/2012-12-20-1040041998_H1SUSMC3_M1_0p01to50Hz_tf.mat

Redid both MC1 and MC3 with DTT: 

/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC1/SAGM1/Data/2012-12-20_0930_H1SUSMC1_M1_WhiteNoise_*_0p01to50Hz.xml
/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC3/SAGM1/Data/2012-12-20_1030_H1SUSMC3_M1_WhiteNoise_*_0p01to50Hz.xml

Both look good to go.
Non-image files attached to this comment
Displaying report 1-1 of 1.