Mark B.
Checked at 06:35. MC1 was done:
/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/MC1/SAGM1/Data/2012-12-19-1040023911_H1SUSMC1_M1_0p01to50Hz_tf.mat
L and T plots are pristine but V, R, P, and Y have major dropouts in centre section, so can't for sure say healthy. Will redo everything with DTT.
MC3 was still running, reporting 167 minutes to go, i.e., about 09:00 am finish. Will probably let run while working on MC1 and then decide whether to redo with DTT.
mark.barton@LIGO.ORG - 12:22, Thursday 20 December 2012 (4983)
Mark B.
MC3 data also had dropouts:
/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC3/SAGM1/Data/2012-12-20-1040041998_H1SUSMC3_M1_0p01to50Hz_tf.mat
Redid both MC1 and MC3 with DTT:
/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC1/SAGM1/Data/2012-12-20_0930_H1SUSMC1_M1_WhiteNoise_*_0p01to50Hz.xml
/ligo/home/controls/mark.barton/0sussvn/HSTS/H1/MC3/SAGM1/Data/2012-12-20_1030_H1SUSMC3_M1_WhiteNoise_*_0p01to50Hz.xml
Both look good to go.