J. Kissel Dave have recently found that there are a small collection of EPICs settings that are both NOT touched by Guardian and NOT monitored in the SDF system (see O3SDFReview in the CDS wiki). Today, during the commissioning period, I reviewed and either monitored or justified why to leave them unmonitored for those channels in the SUS models. Below are detailed notes, but the grand summary is that most of those channels can be monitored and were not, to-date, because they were - old defunct channels that are no longer in use and don't impact the IFO, - controlled by another settings channel via the front-end filter modules with control, or - changing them would not affect the IFO in any substantial way. The remaining channels that I'm leaving unmonitored are - the OPTICALIGN_$(P/Y)_OFFSET channels which are used for alignment and will necessarily be different from lock stretch to lock stretch - the HWWD_STATE channels on the QUADs which are actually readbacks not settings, and are known to be glitchy - the violin mode damping filter settings, which can be tuned during observation. SUS TMSX/Y Now monitored. H1:SUS-TMSX/Y_COMMISH_$(MESSAGE/STATUS) (old defunct dummy EPICs variables to indicate that the suspension was in used for aLIGO install testing and commissioning. Doesn't matter at all, so we'll monitor it just to make this check happy.) H1:SUS-TMSX/Y_M1_OPTICALIGN_P/Y_TRAMP (won't affect anything if changed, but shouldn't be changing, Monitor it just to make the check happy.) H1:SUS-TMSX/Y_M1_TEST_P/Y_TRAMP (won't affect anything if changed, but shouldn't be changing, Monitor it just to make the check happy.) Leaving unmonitored H1:SUS-TMSY_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS SR2 Now monitored. H1:SUS-SR2_BIO_M3_$(OSEMDOF)_CTENABLE (switches the inputs to coil drivers from DAC request to analog input. We ALWAYS want these ON.) H1:SUS-SR2_BIO_M3_$(OSEMDOF)_MSDELAYOFF (addes a delay to the digital compensation half of turning OFF coil driver switchable frequency response. We want these fixed and monitored.) H1:SUS-SR2_BIO_M3_$(OSEMDOF)_MSDELAYON (same as above, but for turning ON the coil driver switchable frequency response.) H1:SUS-SR2_BIO_M3_$(OSEMDOF)_STATEREQ (master control variable for switching the coil driver frequency response. We want these fixed and monitored.) H1:SUS-SR2_COMMISH_MESSAGE (old defunct dummy EPICs variable to indicate that the suspension was in used for aLIGO install testing and commissioning. Doesn't matter at all, so we'll monitor it just to make this check happy.) H1:SUS-SR2_M3_EUL2OSEM_TRAMP (ramp time for the M3 EUL2OSEM matrix. wouldn't affect anything to have it change, but monitor it just to make this check happy.) H1:SUS-SR2_M1_LOCK_P/Y_SW1S_INPT (formerly guardian controlled filter module in filter bank, but shouldn't be changing when in observe, so we want monitored. ) H1:SUS-SR2_M3_EUL2OSEM_SETTING_$(ROW)_$(COLUMN) (M3 EUL2OSEM matrix values *to be loaded if load was hit*. Should be fixed in observe anyway, so we want monitored.) Leaving unmonitored H1:SUS-SR2_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS PR3 Leaving unmonitored H1:SUS-PR3_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS OMC Now Monitored H1:SUS-OM3_M1_TEST_P/Y_SW1S_OFFS (generally unused and off. Would be used for misalignment offsets. Monitor it just to make the check happy.) SUS MC2 Now Monitored H1:SUS-MC2_BIO_M3_$(OSEMDOF)_CTENABLE (switches the inputs to coil drivers from DAC request to analog input. We ALWAYS want these ON.) H1:SUS-MC2_BIO_M3_$(OSEMDOF)_MSDELAYOFF (addes a delay to the digital compensation half of turning OFF coil driver switchable frequency response. We want these fixed and monitored.) H1:SUS-MC2_BIO_M3_$(OSEMDOF)_MSDELAYON (same as above, but for turning ON the coil driver switchable frequency response.) H1:SUS-MC2_BIO_M3_$(OSEMDOF)_STATEREQ (master control variable for switching the coil driver frequency response. We want these fixed and monitored.) H1:SUS-MC2_M3_EUL2OSEM_SETTING_$(ROW)_$(COLUMN) (M3 EUL2OSEM matrix values *to be loaded if load was hit*. Should be fixed in observe anyway, so we want monitored.) Leaving unmonitored H1:SUS-MC2_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS ITMY Now Monitored H1:SUS-ITMY_L2_DRIVEALIGN_$(P/Y)2L_GAIN (A2L gains. shouldn't be changing during observe anymore, a relic of when we weren't constantly controlling the spot positions on the test masses. Also, not replaced by $(P/Y)2L_SPOT_GAIN, which is already monitored.) H1:SUS-ITMY_$(L1/L2/L3)_CAL_LINE_$(CLKGAIN,COSGAIN,SINGAIN,FREQ,TRAMP) (parameters for calibration line injection points. For ITMs we want these OFF and monitored.) H1:SUS-ITMY_BIO_L3_$(OSEMDOF)_SW (Master switch for ESD driver state. Should be monitored.) H1:SUS-ITMY_BIO_L3_MSDELAYOFF (same as SR2 and MC2.) H1:SUS-ITMY_BIO_L3_MSDELAYON H1:SUS-ITMY_BIO_L3_STATEREQ Leaving unmonitored H1:SUS-ITMY_HWWD_STATE (glitchy channel reflecting the status of the HWWD. If monitored, will constantly and errantly kick us out of observing) H1:SUS-ITMY_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) H1:SUS-ITMY_L2_DAMP_MODE??_$(GAIN,TRAMP) (violin mode damping filter settings, continually played with by guardian during observe.) Still under question (why isn't this touched by the guardian?): H1:SUS-ITMY_L2_DAMP_MODE16_SW1S (filters for control of MODE16 violin mode damping filter. Maybe this mode is no longer in used, or not touched by guardian? Seems like it should be,) SUS ITMX Now Monitored H1:SUS-ITMX_M0_LOCK_$(P/Y)_TRAMP (won't affect anything if changed, Monitor it just to make the check happy.) H1:SUS-ITMX_L2_DRIVEALIGN_$(P/Y)2L_GAIN (A2L gains. shouldn't be changing during observe anymore, a relic of when we weren't constantly controlling the spot positions on the test masses. Also, not replaced by $(P/Y)2L_SPOT_GAIN, which is already monitored.) H1:SUS-ITMX_$(L1/L2/L3)_CAL_LINE_$(CLKGAIN,COSGAIN,SINGAIN,FREQ,TRAMP) (parameters for calibration line injection points. For ITMs we want these OFF and monitored.) H1:SUS-ITMX_BIO_L3_$(OSEMDOF)_SW (Master switch for ESD driver state. Should be monitored.) H1:SUS-ITMX_BIO_L3_MSDELAYOFF (same as SR2, MC2, and ITMY.) H1:SUS-ITMX_BIO_L3_MSDELAYON H1:SUS-ITMX_BIO_L3_STATEREQ Leaving unmonitored H1:SUS-ITMX_HWWD_STATE (glitchy channel reflecting the status of the HWWD. If monitored, will constantly and errantly kick us out of observing) H1:SUS-ITMX_L2_DAMP_MODE??_$(GAIN,TRAMP) (violin mode damping filter settings, continually played with by guardian during observe.) SUS IM Now Monitored H1:SUS-IM$(1-4)_COMMISH_MESSAGE (old defunct dummy EPICs variable to indicate that the suspension was in used for aLIGO install testing and commissioning. Doesn't matter at all, so we'll monitor it just to make this check happy.) Leaving unmonitored H1:SUS-IM4_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS HTTS Now Monitored H1:SUS-RM$(1/2)_COMMISH_MESSAGE (old defunct dummy EPICs variable to indicate that the suspension was in used for aLIGO install testing and commissioning. Doesn't matter at all, so we'll monitor it just to make this check happy.) Leaving Unmonitored H1:SUS-RM1_M1_OPTICALIGN_P_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning) SUS ETMY Now Monitored H1:SUS-ETMY_L2_COILOUTF_$(OSEMDOF)_TRAMP (won't affect anything if changed, but shouldn't be changing, Monitor it just to make the check happy.) H1:SUS-ETMX_L2_DRIVEALIGN_$(P/Y)2L_GAIN (A2L gains. shouldn't be changing during observe anymore, a relic of when we weren't constantly controlling the spot positions on the test masses. Also, not replaced by $(P/Y)2L_SPOT_GAIN, which is already monitored.) Leaving unmonitored H1:SUS-ETMY_HWWD_STATE (glitchy channel reflecting the status of the HWWD. If monitored, will constantly and errantly kick us out of observing) H1:SUS-ETMY_L2_DAMP_MODE??_$(GAIN,TRAMP) (violin mode damping filter settings, continually played with by guardian during observe.) SUS ETMX Now Monitored H1:SUS-ETMX_L2_CAL_LINE_TRAMP (won't affect anything if changed, but shouldn't be changing, Monitor it just to make the check happy.) Leaving Unmonitored H1:SUS-ITMX_L2_DAMP_MODE??_$(GAIN,TRAMP) (violin mode damping filter settings, continually played with by guardian during observe.) SUS BS Now monitored H1:SUS-BS_COMMISH_MESSAGE (old defunct dummy EPICs variable to indicate that the suspension was in used for aLIGO install testing and commissioning. Doesn't matter at all, so we'll monitor it just to make this check happy.) Leaving unmonitored H1:SUS-BS_M1_OPTICALIGN_P/Y_OFFSET (continually changes from observe stretch to observe stretch for optical alignment tuning)