Some output jitter investigation

Sheila, Georgia

Today while LLO was commissioning we took some time to look into output jitter. The end goal is to have a projection of OMC ASC to DARM for the noise budget, following similar methods to Koji or Carl

Today we only mostly ran excitations to the POS_Y loop, with various offsets and excitation levels. We also did a couple of excitations to the POS_X loop.

Other things to note:

Images attached to this report
Comments related to this report
georgia.mansell@LIGO.ORG - 16:38, Thursday 13 June 2019 (49898)

I had a look at DARM with and without the large offset in POS_Y, using the online time-dependent-correction-factor corrected channel (in the above alog the 3rd attachment is instead just using CAL-DELTAL_EXTERNAL).

The top plot of the attachment shows DARM with and without this offset, and with and without an excitation. The optical gain reduction with the alignment offset is obvious above 60 Hz, however I do not see any extra jitter coupling. I also plotted the coherence between one of the QPD channels and DARM (all the QPD channels looked very similar), and don't see anything there.

If I understand correctly: Adding the alignment offset increased our excitation coupling by a factor of 2, so given that we don't see extra jitter coupling with the offset our ambient noise is at least a factor of 2 below DARM.

Note: we were limited to offsets between -1 and 6 in the POS_Y degree of freedom: going outside these bounds saturated the OMC suspension.

Images attached to this comment