Displaying report 1-1 of 1.
Reports until 16:00, Friday 14 June 2019
H1 General
travis.sadecki@LIGO.ORG - posted 16:00, Friday 14 June 2019 - last comment - 17:22, Friday 14 June 2019(49920)
Ops Day Shift Summary

TITLE: 06/14 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Commissioning
INCOMING OPERATOR: Ed
SHIFT SUMMARY:  A couple of locklosses early during the first half of the shift.  The second half of the shift has been used for Commissioning since ALS has been having issues relocking.
LOG:

19:56 Kyle and Gerardo to MY

22:32 Kyle and Gerardo back

Comments related to this report
keita.kawabe@LIGO.ORG - 17:22, Friday 14 June 2019 (49926)

I can see from H1:ODC-OBSERVATORY_MODE that there appears to be about 70 minutes of commissioning today even though in reality there was zero.

Please only use

H1:ODC-OBSERVATORY_MODE = COMMISSIONING [40]

for commissioning.

Don't use it for tasks that are CORRECTIVE MAINTENANCE [53] in nature, e.g. fixing problems when IFO doesn't work, even if the commissioners are working on that problem.  That's no different from EE shop trying to identify and eventually replacing broken electronics.

Commissioning is a planned detector improvement project (IFO characterization measurements, noise and/or stability and/or lock sequence improvement etc.). When you find it on a whiteboard for commissioning tasks, that's commissioning.

Displaying report 1-1 of 1.