jeffrey.bartlett@LIGO.ORG - posted 00:08, Tuesday 18 June 2019 - last comment - 00:39, Tuesday 18 June 2019(50014)
Ops Evening Shift Summary
Ops Shift Log: 06/17/2019, Evening Shift 23:00 – 07:00 (16:00 - 00:00) Time - UTC (PT)
State of H1: Locked at NLN, range of 115.9Mpc, with 37.2W of power
Intent Bit: Observing
Support: Georgia
Incoming Operator: TJ
Shift Summary: At 01:27 (18:27) got a CRC error due to problem with H1IOPISCEY. Called Dave B., see aLOG 50009. Lost lock at 01:53 (18:53) as expected when Dave rebooted H1ISCEY. Reset End-Y ISI and HEPI tripped WDs.
 
  At 02:01 (19:01) started relocking. Initially had some issues getting Y-Arm Green to lock. At the time there were several wind gusts in the mid 30mph range. After things settled a bit could reliably lock both arms green. Had to tweak the BS and PRM to get through DRMI_1F. After this, no additional adjustments were needed.
 
   At 03:02 (20:02) and 03:23 (20:23) lost lock at ENG_SOFT_LOOPS. Georgia is looking into these lock losses.
   Have been seeing 30 plus mph gusts at End-X, which is not helping the relocking.
 
   Arrived back at NLN. Accepted several SDF Diffs. Did an INIT on LOCKLOSS_SHUTTER_CHECK node as it was stuck on SHUTTER_FAIL. This was a leftover from the H1ISCEY crash.
   Back in Observing.
 
   Switched to EARTHQUAKE mode for mag5.5 in Tonga. Switched back to WINDY after quake passed.
   The wind remains high (consistently over 20mph) but are laying down a bit.
 
 
Activity Log: Time - UTC (PT)
23:00 (16:00) Take over from Travis
23:11 (16:11) Gerardo – Back from Mid-Y
01:27 (18:27) EY CRC Error (H1IOPISCEY)
01:27 (18:27) Dropped out of Observing – Into Unknown
01:29 (18:29) Dave B. – Looking into the problem
01:53 (18:53) Lockloss – Dave working on recovery of H1IOPISCEY   
02:01 (19:01) Start relocking
03:02 (20:02) Lock loss at ENG_SOFT_LOOPS
03:23 (20:23) Lock loss at ENG_SOFT_LOOPS
03:33 (20:33) Lock loss at CARM_150_PICOMETERS
04:11 (21:11) Locked at NLN
04:15 (21:15) Georgia & Jeff - Cleared SDF Diffs
04:17 (21:17) INIT on LOCKLOSS_SHUTTER_CHECK (was stuck at SHUTTER_FAIL)
04:17 (21:17) Back into Observing mode
05:39 (22:39) Switch to EARTHQUAKE mode for incoming mag 5.5 from Tonga
06:02 (23:02) Switch back to WENDY after EQ passed
07:00 (00:00) Turn over to TJ

 

Comments related to this report
thomas.shaffer@LIGO.ORG - 00:39, Tuesday 18 June 2019 (50016)DetChar, SEI
Tagging @DetChar and SEI for data in seismic's sensor correction configuration transition studies.