Following CPS are over threshold:
FRS 13075
During Tuesday Maintenance, the BS was taken to DAMPED and the CPS Interface chassis was power cycled in the CER. This power cycled the satellite racks as well. I did not un- & re-seat the gauge board cards in the satellite rack which is one thing we do to mitigate the elevated noise on a CPS.