Here is the full list of h1seiex DAQ-CRC error events we have seen since 13th June. There are 20 in total, and each one has exactly the same profile, with h1iopseiex CRC incrementing by 7 each time, and the user models (h1hpietmx, h1isietmx) incrementing by 8.
The first column is the date in June. Note that generally the time of the event is randomly distributed throughout the day exept for two event pairs (marked with +) which are three and six minutes apart.
13 03:57:46.000000Z
13 08:26:19.000000Z
14 20:45:14.000000Z
15 07:14:56.000000Z
15 12:08:52.000000Z
15 19:50:32.000000Z
16 18:37:31.000000Z
17 01:07:17.000000Z
17 17:32:49.000000Z
17 22:49:13.000000Z
19 02:14:14.000000Z
19 11:14:04.000000Z
20 03:04:27.000000Z
20 16:01:39.000000Z
21 07:02:05.000000Z+
21 07:05:39.000000Z+
21 09:59:01.000000Z
23 05:06:11.000000Z
24 04:56:32.000000Z+
24 05:02:10.000000Z+