Reports until 15:32, Wednesday 26 June 2019
H1 CDS
david.barker@LIGO.ORG - posted 15:32, Wednesday 26 June 2019 (50214)
Consolidated IOP SDF into one snap file (safe.snap), turned h1iopiscex DAC-DT On

Jeff K, Dave:

For each IOP model:

1) if safe.snap and OBSERVE.snap were links to separate but equal files, changed OBSERVE link to point to safe.snap file

2) if safe.snap and OBSERVE.snap were links to separate and different files, made safe.snap = OBSERVE.snap and changes OBSERVE link to point to safe.snap file

only h1iopoaf1 needed no changes. 13 IOP models matched 1) and 16 IOP models matched 2) making 30 total IOPs.

Following my discovery that h1iopiscey was not setting its DACDT to On until last week, today Jeff and I turned on h1iopiscex's DACDT.