corey.gray@LIGO.ORG - posted 23:55, Thursday 27 June 2019 (50257)
Locking Notes: Ugly PR_GAIN, Alignment, Prettier PR_GAIN, and PRM SDF Diffs!

Two Types of Symptoms For Locking Locklosses During This Shift Before Alignment:

  1. PR Gain noisy from CARM_OFFSET_REDUCTION all the way to ENGAGE_ASC_FOR_FULL_IFO (example Attachment #1)
  2. Ringing up of PR GAIN & POP18 from ENGAGE_ASC_FOR_FULL_IFO to DARM_TO_DC_READOUT (example Attachment #2)

Something was not happy in ASC land!

LOCKING NOTES:

3:14 Lockloss

New SDF Diff for PRM:  This had to do with Binary IO (BIO) State Request (for Acquire & Low Pass) for PRM.

These were a new set of DIFFS which I had not seen before.  I called Keita first (but I woke him up!), and then talked with Georgia.  She was familiar with the issue.  She mentioned since these were on the M2 stage they are not an issue for us at NOMINAL LOW NOISE since we do not have signals for the M2 coils.  So in the interest of returning to OBSERVING & since this won't affect NLN/Observing, screenshot the channels/diffs, and all windows related to this (See Attachment #3, which shows channels with diffs, and all PRM medm windows involved). 

Will need to trend these channels and/or go through guardian scripts to see what State Request we normally have for PRM, but I'll leave this for others.  Will want to see what happens for the next lock!

6:15 Back to OBSERVING!