mark.barton@LIGO.ORG - posted 14:50, Friday 04 January 2013 - last comment - 08:48, Saturday 05 January 2013(5033)
BS Tfs
Mark B.
Preparing for undamped and damped Matlab TFs on the BS. "Measurement Status" indicator on the MEDM screen should go on automatically when underway and off when done.
Comments related to this report
mark.barton@LIGO.ORG - 08:48, Saturday 05 January 2013 (5036)
Mark B.
The measurement attempt finished on schedule but was a disaster from the point of view of results: the script consistently failed to read data from NDS, even after 25 attempts for each drive segment. This is reminiscent of an old bug that Stuart worked to fix and indeed the same script worked for MC2 the other night. Debugging continues.