travis.sadecki@LIGO.ORG - posted 07:56, Wednesday 03 July 2019 - last comment - 08:39, Wednesday 03 July 2019(50366)
Lockloss 14:54 UTC

Seemingly spontaneous lockloss.  Environment is calm.  No indication of cause.  Sorry TJ!

Comments related to this report
thomas.shaffer@LIGO.ORG - 08:39, Wednesday 03 July 2019 (50369)ISC

PRC2 Y seems to be pulling away sooner than the others. Online lock loss suggests it was PR2 M1 SD?