patrick.thomas@LIGO.ORG - posted 00:31, Tuesday 09 July 2019 (50456)
PSL Status Report - Weekly
FAMIS 11020

    Laser Status:
    Front End Power is 31.85W (should be around 30 W)
    70W Output Power is 69.36W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 6 days, 14 hr 31 minutes (should be days/weeks)
    Reflected power = 10.1Watts
    Transmitted power = 54.36Watts
    PowerSum = 64.46Watts.

    FSS:
    It has been locked for 0 days 3 hr and 47 min (should be days/weeks)
    TPD[V] = 4.934V (min 0.9V)

    ISS:
    The diffracted power is around 2.2%
    Last saturation event was 0 days 3 hours and 51 minutes ago (should be days/weeks)
Displaying report 1-1 of 1.