[Stuart A, Jeff B] Jeff is ready to commence taking transfer functions on the triple test-stand and asked if all the recently updated automated Matlab testing scripts had been deployed. I therefore logged on remotely and svn'd up the following directories:- /ligo3/svncommon/SusSVN/sus/trunk/Common /ligo3/svncommon/SusSVN/sus/trunk/HSTS /ligo3/svncommon/SusSVN/sus/trunk/HLTS and just for good measure... /ligo3/svncommon/SusSVN/sus/trunk/BSFM /ligo3/svncommon/SusSVN/sus/trunk/QUAD Earlier today I committed (rev 3913) of the Schroeder Phase Tools "Matlab_TFs.m" function, which fixed the argument validation for X1 and X2 triple test-stands, allowing HSTS and HLTS optics to be used. This was tested at LLO and has now also been tested and rolled-out on the LHO triple test-stand. An example, for PR3 (HLTS), was added to the end of the "LHO_Matlab_TFs.m" script, demonstrating how to automate taking sequential M1-M1 undamped and undamped Matlab TFs on the LHO (X1) test-stand.