When I came into the control room after maintence, Jeff B was hand aligning ETMY. This is one of the most common things that operators are reporting that they need to do manually while relocking.
One of the things we have considered to make this easier is to make the baffle dither alignment a part of the routine relocking or initial alignment sequence.
Jeff B and I tried using the script (userapps/asc/h1/scripts/ditherAlign.py) to align ETMY only. I had to decrease the power OK threshold to get it to recognize the beam. This didn't result in an alignment that was good enough for the Y arm to grab, so it seems like this won't be a solution for relocking without doing initial alignment.
We then went through the whole dither alignment process, misaligning both test masses and running TMS alignment, aligning the ITM and running it's baffle alignment, then repeating ETMY. All these steps worked fine but they were slow, the dither servo takes about 2 minutes on each PD, the whole process probably will usually take a half hour unless it is sped up.