After the 2.6.1 upgrade, I logged in to confirm that all installed suspensions (and those not installed but with running models) are running appropriately for the condition of their respective suspension. The only thing I'm concerned about is the BS TST system, which shows that the damping loops, though not unstable, add a significant amount of noise when closed (as determined by the speedometers). I don't think this is a flaw of the upgrade, but it something into which we should look further.
Here's a detailed summary:
Summary Model Running Watchdogs OSEMs Centered OSEM OL Compensation Coil Driver BIO Damping Loops SEI/SUS Exchange OSEM Calibration Offset Calibration OpLev Calibration
------- ------------- --------- -------------- -------------------- --------------- ------------- ---------------- ---------------- ------------------ -----------------
ETMY GREAT Yes Armed Good Enough Installed COIL & State 1 M0 & R0 ON ON and functional NOT Installed Installed Installed
ITMY GOOD Yes Armed Good Enough Installed COIL & State 1 M0 & R0 ON Installed but not Receiving NOT Installed Installed Installed
TMSY GOOD Yes Armed Good Enough Installed COIL & State 1 M1 ON Receiving but not Installed NOT Installed NOT Installed N/A
QUAD TST OK Yes (No suspension attached) N/A COIL & State 1 OFF N/A NOT Installed NOT Installed N/A
BS TST BAD Yes Armed Excellent Installed COIL & State 1 M1 ADDS NOISE N/A NOT Installed NOT Installed N/A
MC1 GOOD Yes Armed Good Enough Installed COIL & State 1 M1 ON Receiving but not Installed NOT Installed NOT Installed N/A
MC2 GOOD Yes Armed Excellent Installed COIL & State 1 M1 ON Receiving but not Installed NOT Installed NOT Installed N/A
MC3 GOOD Yes Armed Excellent Installed COIL & State 1 M1 ON Receiving but not Installed NOT Installed NOT Installed N/A
PRM NOT READY Yes (No suspension attached) No infrastructure installed
PR2 GREAT Yes Armed Excellent Installed COIL & State 1 M1 ON ON and functional NOT Installed Installed N/A
PR3 NOT READY Yes (No suspension attached) No infrastructure installed
SR2 NOT READY Yes (No suspension attached) No infrastructure installed
The remaining suspensions (SR3, SRM, ITMX, ETMX, OMC) do not yet have models running.