Displaying report 1-1 of 1.
Reports until 16:46, Wednesday 09 January 2013
H1 CDS
david.barker@LIGO.ORG - posted 16:46, Wednesday 09 January 2013 (5059)
LSC front end started, DAQ expanded

We started the h1lsc0 front end computer to support the mode cleaner commissioning. I had made the IOP model previously, and we installed the LLO lsc user model. We did not install the two other models for this frontend (OMC1 and OMC2).

We took the l1lsc model and converted it to the h1lsc model by doing the following:

The last part was interesting. The PSL part in the LSC model creates H1:PSL-FSS_RFPD_DC channels, which prevented the LHO DAQ from running due to duplicate channels with the H1 PSL FSS model. Later we will remove these channels from the PSL, but for now I have renamed the LSC channels to H1:LSCPSL-FSS_RFPD_DC to allow the DAQ to run.

The DAQ was reconfigued to add the following systems

Displaying report 1-1 of 1.