corey.gray@LIGO.ORG - posted 10:58, Thursday 18 July 2019 - last comment - 00:25, Friday 19 July 2019(50630)
Oddity for ALSy: Camera/video?

After the Hidalgo, Mexico Earthquake lockloss, ISC_LOCK went for LOCKING_ARMS_GREEN, and it appeared to get there with no problem, but the weird thing I noted was ISC_LOCK thought we were in LOCKING_ARMS_GREEN, and the values for ALS x & y on NDSCOPE both looked nominal (over 1.0 counts), BUT the video spot for ALSy did not look right.

Instead of a bright 0:0 mode for ALSy, we had a very faint spot---and ISC_LOCK & green arm power looked OK!  (see attached screen shot)

I unlocked green Y, tweaked alignment only a little, but it would do the same thing.  I would actually see a nice bright 0:0 mode, but it would then immediately drop in intensity on the video (perhaps in 2-steps). 

ISC_LOCK was happy so I moved on.  Still waiting to see if we can live with this (1st attempt did not lock DRMI, so trying it again).

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 11:55, Thursday 18 July 2019 (50633)

Watching the ALSy video a few more times, it looks as if there are 3 steps down in the power (by my eye watching the video).

corey.gray@LIGO.ORG - 13:17, Thursday 18 July 2019 (50635)

Mentioned this to Sheila and her thought was this might possibly be an issue with the Video for ALSY

This Is A New Issue/Feature!

edmond.merilh@LIGO.ORG - 18:42, Thursday 18 July 2019 (50647)

I found that the auto exposure was set to "ON" and the value slider was all the way down. I turned auto exp "OFF" and turned up the exposur to match that of the X camera. It seems to have stayed through another IA/Locking process(es).

thomas.shaffer@LIGO.ORG - 00:25, Friday 19 July 2019 (50650)

July 18th at 13:20 PDT the auto exposure was turned on, most likely by accident. Ed restored this to the x value, I'll restore it to the previous value of 100000 if we lose lock (I don't know if this is an accepted SDF).

Images attached to this comment