opened FRS13311
All front end can see their respective IO Chassis, I'm starting the model recovery.
All models restarted. Jonathan reports DAQ is in good health.
Long range dolphin is down, I'm investigating.
h1cdsrfm computer had restarted itself (it is a diskless front end, but the only one which got rebooted). I had to remember how to start the code since we haven't done so since Nov 2018.
Code is running, bad news is that we are not receiving anything from EY. This could be a possible problem with the EY remote Adnaco chassis. No, I can see all three Dolphin IX cards.
I've tried several reboots of h1cdsrfm, but I still get the problem that IPC from EY to the corner station is failing (CS to EY is working).