h1cdsrfm reporting EY Dolphin link is not operational

Looking at the dmesg kernel messages on h1cdsrfm shows it sees an issue with IXH Adapter 2 (EY). It does not report it as operational. Since corner station to EY data is functional, presumably this is a partial failure of the IX611 card at EY. Looks like a power cycle of h1cdsrfm and the EY adnaco chassis is the next thing to try.

controls@h1cdsrfm ~ $ dmesg |grep "IXH Adapter 0"|grep oper

[   58.163158] IXH Adapter 0 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec

controls@h1cdsrfm ~ $ dmesg |grep "IXH Adapter 1"|grep oper

[   58.168059] IXH Adapter 1 : Link 0 is operational - Link width: x8 - PCIe Gen 2 -- Downtime: 0 sec

controls@h1cdsrfm ~ $ dmesg |grep "IXH Adapter 2"|grep oper

NO Response from last command

Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:30, Wednesday 24 July 2019 (50774)
For the lay-person
    IXH Adapter 2 = dolphin network switch (maybe?)
    IX611 card = long range dolphin network card in side the h1cdsrfm computer.
    EY adnaco chassis = where the dolphin to long range fiber conversion happens