Reports until 22:41, Wednesday 24 July 2019
H1 SUS
travis.sadecki@LIGO.ORG - posted 22:41, Wednesday 24 July 2019 (50799)
Damping ETMy Violin Modes 1 and 6

ETMy Modes 1 and 6 were relatively rung up.  In order to eliminate these as a problem with locking going forward, I spent several hours tonight hunting for better gain settings and damping these modes (Mode 1 was not damping with the preset gain and Mode 6 gain was 0).  The best settings I found for these two modes were:

  Old Gain New Gain
Mode 1 0.100 -0.100
Mode 6 0 0.500