J. Kissel Having lost lock in the same "within a few seconds" timescale from doing nothing but rotate the rotation stage and adjust the "POWER SCALE" -- i.e. take the LASER_PWR -- guardian from POWER_2W to POWER_3W, I'm suspecting PDs falling off of useable area. We not the that IMC global position has moved quite a bit (at the ~10 urad level) from last week -- and since then we've had two major crashes (dolphin crash on Monday, and ) -- Here's a trend of the ISS QPDs. There's a major change on 2019-07-14 ~11:53 UTC (Sunday Jul 14 2019 04:53:00 PDT), but nothing recently of note. Attached is a trend from June 19 2019 to now (prior to June 19th, we're stable at the Jun 19th value since the start of O3).
IM1 and IM2 shifted in pitch, alogged here: alog 50571, and I called in, and talked to the operator, to make them aware.