BS TFs
Mark B.

I did some TFs on the BS using DTT:

/ligo/svncommon/SusSVN/sus/trunk/BSFM/H1/BSTST/SAGM1/Data/2013-01-11_1230_H1SUSBSTST_M1_*_WhiteNoise.xml

It's pretty sick - L and Y are not to bad, but R, T, V and P are nothing like what they're supposed to be.
Non-image files attached to this report
Comments related to this report
betsy.weaver@LIGO.ORG - 15:05, Monday 14 January 2013 (5096)

Travis found and relieved a brushing barrel EQ stop on the top of the Penultimate mass.  Back to TFs.