david.barker@LIGO.ORG - posted 13:03, Monday 14 January 2013 (5094)
h1 HEPI HAM1 model started with temporary ADC

Hugo rebuilt the h1hpiham1 model to use the one working ADC on this system (ADC card 0). We restarted the IOP model h1iopseih16, it had glitched earlier today. Both IOP and HAM1 models were added to the DAQ.

Currently the h1seih16 front end is not connected to the Dolphin fabric. There is no need for IPC currently on HEPI HAM1, so we will keep this off the Dolphin network until the ADC problem is resolved.