jenne.driggers@LIGO.ORG - posted 12:30, Wednesday 31 July 2019 (50947)
Midday Update: The fight to re-find a reproducable ITMY alignment continues

[Niko, Jenne, JeffK]

After a lucky 11 hour lock stretch, an earthquake kicked us out. Now, we're finding ourselves having to pick up the hunt for ITMY alignment reference that produces a robust acquisition sequence where we left off yesterday (see LHO aLOGs 50935, 50939) after the ITMY green camera got accidentally bumped (LHO aLOG 50915).

We're still having intermitten issues with problem (1) from LHO aLOG 50936 : ALS X WFS1 PIT pulls the Xarm green lock off in to the weeds [though now not during LOCKING_ARMS_GREEN, but in the middle of DRMI acquisition], so PRMI/DRMI alignment iterating is slower than we want.

Stay tuned!