Reports until 18:12, Sunday 04 August 2019
H1 General (SUS)
Link
cheryl.vorvick@LIGO.ORG -
posted 18:12, Sunday 04 August 2019
(51019)
H1 out of Observe - violin ETMX mode 13
I noticed the BLRMS striptool traces 6 and 7 (530Hz-980Hz, 1KHz-2KHz) were smoothly increasing, and about to exit the striptool view off the top
found ETMX mode 13 was at 5.3
00:29:10 - H1 to Commissioning, violin guardian to Damping_on_simple
ETMX mode 13 gain set to +30, no other changes
00:37:11 - H1 in Observe
first plot attached shows the BLRMS striptool
second plot attached shows this lock, mode 13 started out at around 2, and grew to 5.3
third plot show 10,000 seconds and how mode 13 was ringing up other modes
Images attached to this report