Displaying report 1-1 of 1.
Reports until 13:01, Wednesday 14 August 2019
H1 CAL (CAL)
travis.sadecki@LIGO.ORG - posted 13:01, Wednesday 14 August 2019 - last comment - 13:09, Wednesday 14 August 2019(51269)
PCal X issues

JeffK noticed that the PCal X was glitching and corrupting the DARM spectrum.  We had a quick look at the PCal MEDM screen and nothing seems awry.  Perhaps more investigation should be done to find the cause of the new glitchiness?

Comments related to this report
travis.sadecki@LIGO.ORG - 13:09, Wednesday 14 August 2019 (51271)

This glitching occured at approximately 20:00 UTC.

Displaying report 1-1 of 1.