ASC Woes....

Have had a 3 attempts dashed by locklosses before getting through various ASC steps.....   Will keep making more attempts and see if I can try to employ the script (alog #51282) to stamp down CONTROL signals when they get ugly (have not tried that yet).  I reckon I will if I keep running into a wall, I'll run an alignment (although the arms & DRMI look fine).

Here are notes on the 1st lock:

7:15 Continuing Locking with this my first Lock#1

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 01:49, Thursday 15 August 2019 (51290)

Lock #3:  lockloss at LOWNOISE COIL DRIVERS

Thought we had a chance on this one as we made it through ASC steps (but maybe I should have hung out at LOWNOISE ASC just to monitor the ASC ERROR signals for a bit).

I did hang out at PREP ASC FOR FULL IFO, ENGAGE ASC FOR FULL IFO, & ENGAGE SOFT LOOPS to watch the ERROR signals...nothing really obvious.  I saw CSOFT pitch get a little bigger, and tried the script JeffK mentions, but did not see any effects on this ERROR signal.

Attached is the ASC ndscope, and here you can see there was no obvious ringing up to address.

NOTE:  Feels like alignment is not an issue here, so will continue with babysitting/babystepping through ISC_LOCK steps.