Templates for comparing the spectrum of the OSEMs

Following up on Sheila's email, I have created new templates for looking into the spectrum of the OSEMs for the following suspensions: ETMX, ETMY, ITMX, ITMY, PRM, SRM. Given below are their location, along with their measurement channels.

ETMX

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMX/Common/Data/2019-08-15_2102_H1SUSETMX_OSEM_ASD.xml

H1:SUS-ETMX_M0_OSEMINF_F1_OUT_DQ      H1:SUS-ETMX_M0_OSEMINF_F2_OUT_DQ       H1:SUS-ETMX_M0_OSEMINF_F3_OUT_DQ 

H1:SUS-ETMX_M0_OSEMINF_LF_OUT_DQ      H1:SUS-ETMX_M0_OSEMINF_RT_OUT_DQ        H1:SUS-ETMX_M0_OSEMINF_SD_OUT_DQ

H1:SUS-ETMX_M0_OSEMINF_SD_OUT_DQ     H1:SUS-ETMX_R0_OSEMINF_F1_OUT_DQ        H1:SUS-ETMX_R0_OSEMINF_F2_OUT_DQ

H1:SUS-ETMX_R0_OSEMINF_F3_OUT_DQ      H1:SUS-ETMX_R0_OSEMINF_LF_OUT_DQ         H1:SUS-ETMX_R0_OSEMINF_RT_OUT_DQ     

H1:SUS-ETMX_R0_OSEMINF_SD_OUT_DQ

ETMY

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ETMY/Common/Data/2019-08-20_1835_H1SUSETMY_OSEM_ASDs.xml

H1:SUS-ETMY_M0_OSEMINF_F1_OUT_DQ      H1:SUS-ETMY_M0_OSEMINF_F2_OUT_DQ       H1:SUS-ETMY_M0_OSEMINF_F3_OUT_DQ 

H1:SUS-ETMY_M0_OSEMINF_LF_OUT_DQ      H1:SUS-ETMY_M0_OSEMINF_RT_OUT_DQ        H1:SUS-ETMY_M0_OSEMINF_SD_OUT_DQ

H1:SUS-ETMY_M0_OSEMINF_SD_OUT_DQ     H1:SUS-ETMY_R0_OSEMINF_F1_OUT_DQ        H1:SUS-ETMY_R0_OSEMINF_F2_OUT_DQ

H1:SUS-ETMY_R0_OSEMINF_F3_OUT_DQ      H1:SUS-ETMY_R0_OSEMINF_LF_OUT_DQ         H1:SUS-ETMY_R0_OSEMINF_RT_OUT_DQ     

H1:SUS-ETMY_R0_OSEMINF_SD_OUT_DQ

ITMX

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMX/Common/Data/2019-08-20_1833_H1SUSITMX_OSEM_ASDs.xml

H1:SUS-ITMX_M0_OSEMINF_F1_OUT_DQ      H1:SUS-ITMX_M0_OSEMINF_F2_OUT_DQ       H1:SUS-ITMX_M0_OSEMINF_F3_OUT_DQ 

H1:SUS-ITMX_M0_OSEMINF_LF_OUT_DQ      H1:SUS-ITMX_M0_OSEMINF_RT_OUT_DQ        H1:SUS-ITMX_M0_OSEMINF_SD_OUT_DQ

H1:SUS-ITMX_M0_OSEMINF_SD_OUT_DQ     H1:SUS-ITMX_R0_OSEMINF_F1_OUT_DQ        H1:SUS-ITMX_R0_OSEMINF_F2_OUT_DQ

H1:SUS-ITMX_R0_OSEMINF_F3_OUT_DQ      H1:SUS-ITMX_R0_OSEMINF_LF_OUT_DQ         H1:SUS-ITMX_R0_OSEMINF_RT_OUT_DQ     

H1:SUS-ITMX_R0_OSEMINF_SD_OUT_DQ

ITMY

/ligo/svncommon/SusSVN/sus/trunk/QUAD/H1/ITMY/Common/Data/2019-08-20_1844_H1SUSITMY_OSEM_ASDs.xml

H1:SUS-ITMY_M0_OSEMINF_F1_OUT_DQ      H1:SUS-ITMY_M0_OSEMINF_F2_OUT_DQ       H1:SUS-ITMY_M0_OSEMINF_F3_OUT_DQ 

H1:SUS-ITMY_M0_OSEMINF_LF_OUT_DQ      H1:SUS-ITMY_M0_OSEMINF_RT_OUT_DQ        H1:SUS-ITMY_M0_OSEMINF_SD_OUT_DQ

H1:SUS-ITMY_M0_OSEMINF_SD_OUT_DQ     H1:SUS-ITMY_R0_OSEMINF_F1_OUT_DQ        H1:SUS-ITMY_R0_OSEMINF_F2_OUT_DQ

H1:SUS-ITMY_R0_OSEMINF_F3_OUT_DQ      H1:SUS-ITMY_R0_OSEMINF_LF_OUT_DQ         H1:SUS-ITMY_R0_OSEMINF_RT_OUT_DQ     

H1:SUS-ITMY_R0_OSEMINF_SD_OUT_DQ

PRM

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/PRM/Common/Data/2019-08-20_1932_H1SUSPRM_OSEM_ASDs.xml

H1:SUS-PRM_M1_OSEMINF_LF_OUT_DQ    H1:SUS-PRM_M1_OSEMINF_RT_OUT_DQ    H1:SUS-PRM_M1_OSEMINF_SD_OUT_DQ

H1:SUS-PRM_M1_OSEMINF_T1_OUT_DQ    H1:SUS-PRM_M1_OSEMINF_T2_OUT_DQ    H1:SUS-PRM_M1_OSEMINF_T3_OUT_DQ

SRM

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/SRM/Common/Data/2019-08-20_1907_H1SUSSRM_OSEM_ASDs.xml

H1:SUS-SRM_M1_OSEMINF_LF_OUT_DQ    H1:SUS-SRM_M1_OSEMINF_RT_OUT_DQ    H1:SUS-SRM_M1_OSEMINF_SD_OUT_DQ

H1:SUS-SRM_M1_OSEMINF_T1_OUT_DQ    H1:SUS-SRM_M1_OSEMINF_T2_OUT_DQ    H1:SUS-SRM_M1_OSEMINF_T3_OUT_DQ

Also, please find attached the results from today's measurements, during Tuesday maintenance downtime. Later, I will compare this when the IFO is locked and observing.