Ops Day Mid-Shift Summary
   All going well until 17:39 (10:39) unknown lockloss. Wind was coming down at the time and primary microseism was improving. Then the Z-axis shot up to 0.09um/s. It bounced around for about 30 minutes, and then dropped back down to about 0.01um/s. Nothing on USGS or SEIMON. 

   Relocking has been a bit of a chore so far. Had to work on ALS X several times. After two attempts at DRMI_1F and PRMI states, had to go through CHECK_MITCH_FRINGES to get DRMI_1F to lock. Tweaked PRM and SRM to get a little better buildup. 

   Things going well until a lockloss at ENGAGE_SOFT_LOOPS. Running buck up through the locking sequence.  