Displaying report 1-1 of 1.
Reports until 20:15, Monday 26 August 2019
H1 AOS
corey.gray@LIGO.ORG - posted 20:15, Monday 26 August 2019 - last comment - 22:03, Monday 26 August 2019(51532)
Mid Shift Status

Lockloss at 2:15 (thus ending 30hrs of being locked & observing).

Green Y-arm and PRMI did not look great afer 30+min of trying to make it work, so just finished up an INITIAL ALIGNMENT and now trying to lock again.

Comments related to this report
corey.gray@LIGO.ORG - 22:03, Monday 26 August 2019 (51533)

Locking wasn't trivial or timely.  Had a few locklosses (logged in my summary), and definitely needed to babysit the ASC steps and also reduce ERROR signals (most recent lock which got us to NLN required a good 30min to babysit ASC!  But we are back to Observing finally (after over 2.5hrs of being down).

Displaying report 1-1 of 1.