Ops Shift Log: 08/31/2019, Day Shift 07:00 – 15:00 (00:00 - 08:00) Time - UTC (PT)
State of H1: Locked at NLN, Range = 119.6Mpc
Intent Bit: Observing
Support: Hugh, Peter
Incoming Operator: Niko
Shift Summary: Since relocking, the IFO has performed well. Saw a 120Mpc range once. Environmental remains good. The tidal problems from earlier have not reappeared, but it has only been about 4.5 hours since relocking.
Activity Log: Time - UTC (PT)
07:00 (00:00) Take over from Cheryl
07:30 (00:00) Call Hugh about Tidal problem
07:41 (00:41) Drop out of Observing – Tidal Problem?
07:57 (00:57) Back in Observing – Why?
07:58 (00:58) GRB Alert – Long, spoke with LLO, Ignored
08:44 (01:44) Lockloss – Tidal
08:47 (01:47) Hold locking green to let the tidal bleed off
09:03 (02:03) Start relocking
09:38 (02:38) Lockloss at ENGAGE_ASC_FOR_FULL_IFO
10:25 (03:25) Locked at NLN
10:25 (03:35) No SDF – Back in Observing
15:00 (08:00) Turn over to Niko
Added plot of current tidal.